Functions & features:
1. With voice indication all around the operation.
2. LCD screen indication.
3. Total 32 wirelesss zones: each zone enable to learn code automatically or
enter code manually on the keypad.
4. Total 8 wired zones, connect resistor on wired zone terminal to achieve N/O
or N/C alarm.
5. Enable enroll total 8 wireless remoters, 8 electronic switch, 1pc of wireless
doorbell and unlimited for quantity of one way wireless siren.
6. Zone programmable: Alarm type and delay or instant alarm etc. setting can be
modified.
7. Wireless detectors can be enrolled or deleted separately or simultaneously.
8. Six voice alarm receiving phone, two for CMS, four for private alarm
receiving.
9. Clock & event list: built-in clock, can be set according to local time.
10. Status inspection function: Enable record and inquiry 120 alarm event
message. Messages include alarm time and alarm type such as anti-tamper,
detector alarm, tel-line off,arm, disarm, system setting, battery low voltage.
Alarm zone number and type can be inquired.
11. Password operation: Administrator password is for systems setting such as
adding or delecting detector, zone type change etc. User password is to make
common operation such as arm, disarm, remote controling. Both passwords can be
modified.
12. User code can be set as 4, 6 or 8 digits according to quantity of users.
13. Alarm type auto identify: After alarm triggered, LCD screen on the panel
will display alarm zone#, alarm type, alarm icon. When connect to CMS, panel
will report details.
14. Compatible with CSM machine: Support contact ID. Report alarm to CMS,
arm/disarm to CMS optional.
15. Remote control: Enable to remote control the system via telephone such as
arm/disarm, listen to the spot, trigger siren, switch on/off electronic
appliance etc.
16. Vandal-proof function: Wire between panel and detector cut off or telephone
cut off will make alarm.
17. Tamper-resistant: Panel removing or open will make alarm.
18. Timing arm/disarm: Enable to set 4 group arm/disarm time.
19. Timing testing: Panel will send signal to CMS to test the panel on-line
status at testing time.
20. Siren: The panel with built-in siren, it can also enroll extension wireless
siren. Both can be settled on/off when alarming.
21. Electronic appliance control: Enable remote inquiry and control teh on/off
status of electronic appliance. And also enable to switch on/off manually.
22. Wired/wireless zone real time monitoring: Active real time monitoring
function, then if zone with trouble when doing arm/disarm operation, the panel
will indicate zone fault.
23. With wireless repeater, the transmitting distance from wireless detector to
panel can reach to 3~5km.
24. Wireless detector low battery warning: It will send siganl to panel every
one or two hour. Alarm panel will sound dee dee and LCD display low battery icon
with zone number.The panel will also report to CMS and preset alarm receiving
phone No.
25. Tel-line off and wireless transfer function: panel make alarm or under arm
status, but find out that tel-line off, panel will send signal to preset
neighbour panel and the neighbour panel report alarm instead.
26. Can enable the panel siren by pressing the emergency key on the panel or the
remote controller.
27. GSM alarm function: GSM alarm report to user and alarm report to CMS in CID
format. GSM & PSTN priority can be selected.